Solar and Energy Storage by Lifestyle Construction & Supplies
Charge Controllers for Solar, Wind and Hybrid Systems
MPPT and PWM solar charge controllers for battery systems from low voltage up to 600VDC, plus wind and wind solar hybrid controllers with dump load protection. Every model below carries its full published description and specification so you can match voltage, current and protection to your system before you ask for a quote.
MPPT Solar Charge Controllers
Maximum power point tracking controllers for off grid solar systems, with tracking efficiency up to 99 percent and three stage charging for longer battery life.
Rack Mount MPPT Solar Charge Controller
192V-600VDC Rack Mount MPPT Solar Charger Controller
1. High speed & performance 32bit processor, advanced EMC design
2. Advanced MPPT tracking algorithm, the tracking efficiency more than 99%
3. High performance IGBT power module as electronic switch, plus multiphase synchronous rectification technology, improves the stable greatly
4. Ultrafast maximum power point tracking speed to ensure tracking efficiency
5. Perfect battery protection function and advanced battery activation technology which increases battery lifespan 30% at least and improves the system performance
6. Widely PV arrays’ voltage input, this can save the cost of PV combiner box, wires and construction
7. Full enclosed duct design and high-speed fan for cooling makes the controller suitable for various harsh environments
8. 3’’ LCD screen and LED indicators show working parameters and system status
9. Parameters can be adjusted through touching keys in LCD panel
10. Users can check the power generation of daily, monthly and total through the statistical function of generating capacity (SOC)
11. Complete menu display and operation, plus the humanized design of browsing interface, makes the operation more easy
12.It shows the environment temperature, data and real time, auto temperature compensation function
13.Twice protection function to protect battery from damage when the power switch is down
14. Standard Modbus communication protocol for RS-485 or GPRS communication to extend the communication distance (optional function)
| Specification and model | LCS-MPPT-01V、 LCS-MPPT-01(216)V、 LCS-MPPT-01V | LCS-MPPT-01V、 LCS-MPPT-01(380)V | LCS-MPPT-01V | ||||||
| Battery bank voltage | 192V、 220V(216V)、 240V | 360V、384V(380V) | 480V | ||||||
| Rated charging current | 50A | 80A | 100A | 50A | 80A | 100A | 50A | 60A | 80A |
| Controller charging method | MPPT (maximum power point tracking) | ||||||||
| Controller tracking efficiency | ≥99% | ≥99% | ≥99% | ||||||
| PV module open circuit voltage | DC800V | DC800V | 850VDC | ||||||
| MPPT tracking start voltage | Vbat(actual battery voltage)+20V | ||||||||
| PV start charging voltage | Vbat(actual battery voltage)+10V | ||||||||
| Maximum connected PV module power | 9.6KW 11.0KW 12.0KW | 15.2KW 17.6KW 19.2KW | 19.2KW 22.0KW 24.0KW | 18.0KW 19.2KW | 28.8KW 30.7KW | 36.0KW 38.4KW | 24.0KW | 28.8KW | 38.4KW |
| Charging method | Three stage charging: MPPT fast charge, equalize (constant voltage), float | ||||||||
| Human machine interface | LCD display screen, touch buttons | ||||||||
| Cooling method | Intelligent temperature controlled air cooling | ||||||||
| Communication method | RS485 communication, standard Modbus protocol, optional DTU module enables wireless remote monitoring | ||||||||
| Altitude of use area | Up to 3000 m, derating required above 3000 m | ||||||||
| Working environment temperature | -25℃~+55℃ | ||||||||
| Equipment protection level | IP21 | ||||||||
| Equipment net weight | 25kg | 28Kg | 25Kg | 28Kg | 25Kg | 28Kg | |||
| Equipment dimensions | 494*384*187mm |

192V to 600VDC High Voltage MPPT Solar Charge Controller
192V-600VDC high voltage MPPT charge controller
1. High speed & performance 32bit processor, advanced EMC design
2. Advanced MPPT tracking algorithm, the tracking efficiency more than 99%
3. High performance IGBT power module as electronic switch, plus multiphase synchronous rectification technology, improves the stable greatly
4. Ultrafast maximum power point tracking speed to ensure tracking efficiency
5. Perfect battery protection function and advanced battery activation technology which increases battery lifespan 30% at least and improves the system performance
6. Widely PV arrays’ voltage input, this can save the cost of PV combiner box, wires and construction
7. Full enclosed duct design and high-speed fan for cooling makes the controller suitable for various harsh environments
8. 3’’ LCD screen and LED indicators show working parameters and system status
9. Parameters can be adjusted through touching keys in LCD panel
10. Users can check the power generation of daily, monthly and total through the statistical function of generating capacity (SOC)
11. Complete menu display and operation, plus the humanized design of browsing interface, makes the operation more easy
12.It shows the environment temperature, data and real time, auto temperature compensation function
13.Twice protection function to protect battery from damage when the power switch is down
14. Standard Modbus communication protocol for RS-485 or GPRS communication to extend the communication distance (optional function)
| Specification and model | LCS-MPPT-02V、 LCS-MPPT-02(216)V、 LCS-MPPT-02V | LCS-MPPT-02V、 LCS-MPPT-02(380)V | LCS-MPPT-02V | ||||||
| Battery bank voltage | 192V、 220V(216V)、 240V | 360V、384V(380V) | 480V | ||||||
| Rated charging current | 50A | 80A | 100A | 50A | 80A | 100A | 50A | 60A | 80A |
| Controller charging method | MPPT (maximum power point tracking) | ||||||||
| Controller tracking efficiency | ≥99% | ≥99% | ≥99% | ||||||
| PV module open circuit voltage | DC800V | DC800V | 850VDC | ||||||
| MPPT tracking start voltage | Vbat(actual battery voltage)+20V | ||||||||
| PV start charging voltage | Vbat(actual battery voltage)+10V | ||||||||
| Maximum connected PV module power | 9.6KW 11.0KW 12.0KW | 15.2KW 17.6KW 19.2KW | 19.2KW 22.0KW 24.0KW | 18.0KW 19.2KW | 28.8KW 30.7KW | 36.0KW 38.4KW | 24.0KW | 28.8KW | 38.4KW |
| Charging method | Three stage charging: MPPT fast charge, equalize (constant voltage), float | ||||||||
| Human machine interface | LCD display screen, touch buttons | ||||||||
| Cooling method | Intelligent temperature controlled air cooling | ||||||||
| Communication method | RS485 communication, standard Modbus protocol, optional DTU module enables wireless remote monitoring | ||||||||
| Altitude of use area | Up to 3000 m, derating required above 3000 m | ||||||||
| Working environment temperature | -25℃~+55℃ | ||||||||
| Equipment protection level | IP21 | ||||||||
| Equipment net weight | 25kg | 28Kg | 25Kg | 28Kg | 25Kg | 28Kg | |||
| Equipment dimensions | 494*384*187mm |

Solar Charge Controllers
PWM solar charge controllers in rack mount, wall mount, cabinet and drawer formats, covering battery systems across a wide voltage and current range.
48V Solar Charge Controller, 30A to 60A
PWM charging uses pulse charging, in which the charging current pulse cycle sends out discontinuous current pulses to charge the battery. The intermittent charging pause process allows the battery a sufficient reaction time, reduces gas generation, lightens the internal pressure of the battery and improves the acceptance rate of the charging current, so the battery can absorb more power.
High performance 32 bit processor core with excellent EMC design.
High efficiency PWM charging mode with three stage charging control.
High precision sampling accuracy.
Complete system protection functions including overcharge, overdischarge, overload, short circuit, reverse connection protection and lightning protection.
Uses IGBT or MOSFET as electronic switches, with no mechanical switches.
LCD liquid crystal display shows the current operating status parameters of the system.
New SOC calculation displays the real time battery capacity.
Military grade components give the product good stability.
Power generation statistics function, for viewing daily, monthly and total power generation.
Heat dissipation air duct design, suitable for harsh environments.
Multiple machines can be connected in parallel.
DC output function (optional).
Standard Modbus communication protocol based on the RS 485 communication bus (optional).
| Model | LCS-SCC-01 48V-80A | LCS-SCC-01 48V-100A | LCS-SCC-01 48V-150A |
| Rated charging current | 80 A | 120 A | 150 A |
| Battery bank rated voltage | 48 VDC | ||
| Electrical parameters | |||
| Three stage charging method | Fast charge, equalize, float | ||
| Battery equalize charging voltage | 57.6V [ adjustable ] | ||
| Battery float charging voltage | 55.2V [ adjustable ] | ||
| PV array limit voltage | ≤ 100V | ||
| Night standby loss | < 0.5W | ||
| Working temperature range | -25℃ ~ +60℃ | ||
| Permitted ambient humidity | 0% ~ 98% no condensation | ||
| Communication port | RS485 (optional) | ||
| Mechanical parameters | |||
| Wiring terminals | TC series barrier type wiring | ||
| Display method | LCD white backlight | ||
| Display language | English | ||
| Protection level | IP20 [ indoor ] | ||
| Noise | < 30 dBA | ||
| Installation method | Wall mounted | ||
| External dimensions [ width depth height ] | 345 *395 *155 [mm]( subject to actual dimensions ) | ||
| Net weight | 12KG( subject to actual weight ) |
96V PWM PV Charge Controller, 30A to 60A
PWM charging uses pulse charging, in which the charging current pulse cycle sends out discontinuous current pulses to charge the battery. The intermittent charging pause process allows the battery a sufficient reaction time, reduces gas generation, lightens the internal pressure of the battery and improves the acceptance rate of the charging current, so the battery can absorb more power.
High performance 32 bit processor core with excellent EMC design.
High efficiency PWM charging mode with three stage charging control.
High precision sampling accuracy.
Complete system protection functions including overcharge, overdischarge, overload, short circuit, reverse connection protection and lightning protection.
Uses IGBT or MOSFET as electronic switches, with no mechanical switches.
LCD liquid crystal display shows the current operating status parameters of the system.
New SOC calculation displays the real time battery capacity.
Military grade components give the product good stability.
Power generation statistics function, for viewing daily, monthly and total power generation.
Heat dissipation air duct design, suitable for harsh environments.
Multiple machines can be connected in parallel.
DC output function (optional).
Standard Modbus communication protocol based on the RS 485 communication bus (optional).
| Model | LCS-SCC-02 96V-50A | LCS-SCC-02 96V-100A | LCS-SCC-02 96V-150A |
| Rated charging current | 50 A | 100 A | 150 A |
| Battery bank rated voltage | 96 VDC | ||
| Electrical parameters | |||
| Three stage charging method | Fast charge, equalize, float | ||
| Battery equalize charging voltage | 115.2V [ adjustable ] | ||
| Battery float charging voltage | 100.4V [ adjustable ] | ||
| PV array limit voltage | ≤ 200V | ||
| Night standby loss | < 0.5W | ||
| Working temperature range | -25℃ ~ +60℃ | ||
| Permitted ambient humidity | 0% ~ 98% no condensation | ||
| Communication port | RS485 (optional) | ||
| Mechanical parameters | |||
| Wiring terminals | TC series barrier type wiring | ||
| Display method | LCD white backlight | ||
| Display language | English | ||
| Protection level | IP20 [ indoor ] | ||
| Noise | < 30 dBA | ||
| Installation method | Wall mounted | ||
| External dimensions [ width depth height ] | 345 *395 *155 [mm]( subject to actual dimensions ) | ||
| Net weight | 12KG( subject to actual weight ) |
192V PWM Rack Mount Charge Controller, 30A to 100A
PWM charging uses pulse charging, in which the charging current pulse cycle sends out discontinuous current pulses to charge the battery. The intermittent charging pause process allows the battery a sufficient reaction time, reduces gas generation, lightens the internal pressure of the battery and improves the acceptance rate of the charging current, so the battery can absorb more power.
High performance 32 bit processor core with excellent EMC design.
High efficiency PWM charging mode with three stage charging control.
High precision sampling accuracy.
Complete system protection functions including overcharge, overdischarge, overload, short circuit, reverse connection protection and lightning protection.
Uses IGBT or MOSFET as electronic switches, with no mechanical switches.
LCD liquid crystal display shows the current operating status parameters of the system.
New SOC calculation displays the real time battery capacity.
Military grade components give the product good stability.
Power generation statistics function, for viewing daily, monthly and total power generation.
Heat dissipation air duct design, suitable for harsh environments.
Multiple machines can be connected in parallel.
DC output function (optional).
Standard Modbus communication protocol based on the RS 485 communication bus (optional).
| Model | LCS-SCC-03 192V-30A | LCS-SCC-03 192V-50A | LCS-SCC-03 192-100A |
| Rated charging current | 30 A | 50 A | 100 A |
| Battery bank rated voltage | 192 VDC | ||
| Electrical parameters | |||
| Three stage charging method | Fast charge, equalize, float | ||
| Battery equalize charging voltage | 230.4V [ adjustable ] | ||
| Battery float charging voltage | 220.8V [ adjustable ] | ||
| PV array limit voltage | ≤ 380V | ||
| Night standby loss | < 1.0W | ||
| Working temperature range | -25℃ ~ +60℃ | ||
| Permitted ambient humidity | 0% ~ 98% no condensation | ||
| Communication port | RS485 (optional) | ||
| Mechanical parameters | |||
| Wiring terminals | TC series barrier type wiring | ||
| Display method | LCD white backlight | ||
| Display language | English | ||
| Protection level | IP20 [ indoor ] | ||
| Noise | < 30 dBA | ||
| Installation method | Wall mounted | ||
| External dimensions [ width depth height ] | 345 *395 *155 [mm]( subject to actual dimensions ) | ||
| Net weight | 12KG( subject to actual weight ) |
220V PWM Charge Controller, 30A, 50A and 80A
PWM charging uses pulse charging, in which the charging current pulse cycle sends out discontinuous current pulses to charge the battery. The intermittent charging pause process allows the battery a sufficient reaction time, reduces gas generation, lightens the internal pressure of the battery and improves the acceptance rate of the charging current, so the battery can absorb more power.
High performance 32 bit processor core with excellent EMC design.
High efficiency PWM charging mode with three stage charging control.
High precision sampling accuracy.
Complete system protection functions including overcharge, overdischarge, overload, short circuit, reverse connection protection and lightning protection.
Uses IGBT or MOSFET as electronic switches, with no mechanical switches.
LCD liquid crystal display shows the current operating status parameters of the system.
New SOC calculation displays the real time battery capacity.
Military grade components give the product good stability.
Power generation statistics function, for viewing daily, monthly and total power generation.
Heat dissipation air duct design, suitable for harsh environments.
Multiple machines can be connected in parallel.
DC output function (optional).
Standard Modbus communication protocol based on the RS 485 communication bus (optional).
| System parameters | |||
| Model | LCS-SCC-04 220V-30A | LCS-SCC-04 220V-50A | LCS-SCC-04 220V-80A |
| PV module rated power | 6.6KW | 11.0KW | 17.6 KW |
| Rated charging current | 30 A | 50 A | 80 A |
| Battery bank rated voltage | 220VDC | ||
| Electrical parameters | |||
| Three stage charging method | Constant current, equalize, float | ||
| Battery equalize charging voltage | 264.0V [adjustable] | ||
| Battery float charging voltage | 247.5V [adjustable] | ||
| PV module open circuit voltage | ≤396 V | ||
| Night standby loss | ≤15 mA | ||
| Working temperature range | -25℃ ~ +60℃ | ||
| Permitted ambient humidity | 0%~98% no condensation | ||
| Communication port | RS485(optional) | ||
| External overview | |||
| Wiring terminals | TC series barrier type wiring | ||
| Display method | LED [128*68dot matrix,white backlight] | ||
| Display language | English | ||
| Protection level | IP20 [indoor] | ||
| Noise | <30 dBA | ||
| Installation method | Wall mounted | ||
| External dimensions[width depth height] | 345 *395 *155 [mm](subject to actual dimensions) | ||
| Net weight | 12KG(subject to actual weight) |
240V PV Controller, 100A, 120A and 150A
PWM charging uses pulse charging, in which the charging current pulse cycle sends out discontinuous current pulses to charge the battery. The intermittent charging pause process allows the battery a sufficient reaction time, reduces gas generation, lightens the internal pressure of the battery and improves the acceptance rate of the charging current, so the battery can absorb more power.
High performance 32 bit processor core with excellent EMC design.
High efficiency PWM charging mode with three stage charging control.
High precision sampling accuracy.
Complete system protection functions including overcharge, overdischarge, overload, short circuit, reverse connection protection and lightning protection.
Uses IGBT or MOSFET as electronic switches, with no mechanical switches.
LCD liquid crystal display shows the current operating status parameters of the system.
New SOC calculation displays the real time battery capacity.
Military grade components give the product good stability.
Power generation statistics function, for viewing daily, monthly and total power generation.
Heat dissipation air duct design, suitable for harsh environments.
Multiple machines can be connected in parallel.
DC output function (optional).
Standard Modbus communication protocol based on the RS 485 communication bus (optional).
| Model | LCS-SCC-05 240V-100A | LCS-SCC-05 240V-120A | LCS-SCC-05 240V-150A |
| PV module rated power | 24KW | 28.8KW | 36 KW |
| Rated charging current | 100 A | 120 A | 150 A |
| Battery bank rated voltage | 240VDC | ||
| Electrical parameters | |||
| Three stage charging method | Constant current, equalize, float | ||
| Battery equalize charging voltage | 288.0V [adjustable] | ||
| Battery float charging voltage | 270.0V [adjustable] | ||
| PV module open circuit voltage | ≤432 V | ||
| Night standby loss | ≤15 mA | ||
| Working temperature range | -25℃ ~ +60℃ | ||
| Permitted ambient humidity | 0%~98% no condensation | ||
| Communication port | RS485(optional) | ||
| External overview | |||
| Wiring terminals | TC series barrier type wiring | ||
| Display method | LED [128*68dot matrix,white backlight] | ||
| Display language | English | ||
| Protection level | IP20 [indoor] | ||
| Noise | <30 dBA | ||
| Installation method | Wall mounted | ||
| External dimensions[width depth height] | 345 *395 *155 [mm](subject to actual dimensions) | ||
| Net weight | 15KG(subject to actual weight) |
360V Battery Charge Controller, 30A, 50A and 100A
PWM charging uses pulse charging, in which the charging current pulse cycle sends out discontinuous current pulses to charge the battery. The intermittent charging pause process allows the battery a sufficient reaction time, reduces gas generation, lightens the internal pressure of the battery and improves the acceptance rate of the charging current, so the battery can absorb more power.
High performance 32 bit processor core with excellent EMC design.
High efficiency PWM charging mode with three stage charging control.
High precision sampling accuracy.
Complete system protection functions including overcharge, overdischarge, overload, short circuit, reverse connection protection and lightning protection.
Uses IGBT or MOSFET as electronic switches, with no mechanical switches.
LCD liquid crystal display shows the current operating status parameters of the system.
New SOC calculation displays the real time battery capacity.
Military grade components give the product good stability.
Power generation statistics function, for viewing daily, monthly and total power generation.
Heat dissipation air duct design, suitable for harsh environments.
Multiple machines can be connected in parallel.
DC output function (optional).
Standard Modbus communication protocol based on the RS 485 communication bus (optional).
| Model | LCS-SCC-06 360V-30A | LCS-SCC-06 360V-50A | LCS-SCC-06 360V-100A |
| PV module rated power | 10.8KW | 18KW | 36 KW |
| Rated charging current | 30 A | 50 A | 100 A |
| Battery bank rated voltage | 360VDC | ||
| Electrical parameters | |||
| Three stage charging method | Constant current, equalize, float | ||
| Battery equalize charging voltage | 432.0V [adjustable] | ||
| Battery float charging voltage | 405.0V [adjustable] | ||
| PV module open circuit voltage | ≤650 V | ||
| Night standby loss | ≤10 mA | ||
| Working temperature range | -25℃ ~ +60℃ | ||
| Permitted ambient humidity | 0%~98% no condensation | ||
| Communication port | RS485(optional) | ||
| External overview | |||
| Wiring terminals | TC series barrier type wiring | ||
| Display method | LED [128*68dot matrix,white backlight] | ||
| Display language | English | ||
| Protection level | IP20 [indoor] | ||
| Noise | <30 dBA | ||
| Installation method | Wall mounted | ||
| External dimensions[width depth height] | 345 *395 *155 [mm](subject to actual dimensions) | ||
| Net weight | 13KG(subject to actual weight) |
540V High Voltage Large Current Charge Controller, 150A, 200A and 300A
PWM charging uses pulse charging, in which the charging current pulse cycle sends out discontinuous current pulses to charge the battery. The intermittent charging pause process allows the battery a sufficient reaction time, reduces gas generation, lightens the internal pressure of the battery and improves the acceptance rate of the charging current, so the battery can absorb more power.
High performance 32 bit processor core with excellent EMC design.
High efficiency PWM charging mode with three stage charging control.
High precision sampling accuracy.
Complete system protection functions including overcharge, overdischarge, overload, short circuit, reverse connection protection and lightning protection.
Uses IGBT or MOSFET as electronic switches, with no mechanical switches.
LCD liquid crystal display shows the current operating status parameters of the system.
New SOC calculation displays the real time battery capacity.
Military grade components give the product good stability.
Power generation statistics function, for viewing daily, monthly and total power generation.
Heat dissipation air duct design, suitable for harsh environments.
Multiple machines can be connected in parallel.
DC output function (optional).
Standard Modbus communication protocol based on the RS 485 communication bus (optional).
| Model | LCS-SCC-07 540V-150A | LCS-SCC-07 540V-200A | LCS-SCC-07 540V-300A |
| PV module rated power | 81KW | 108KW | 162KW |
| Rated charging current | 150 A | 200 A | 300 A |
| Battery bank rated voltage | 540VDC | ||
| Electrical parameters | |||
| Three stage charging method | Constant current, equalize, float | ||
| Battery equalize charging voltage | 648.0V [adjustable] | ||
| Battery float charging voltage | 640.0V [adjustable] | ||
| PV module open circuit voltage | ≤900 V | ||
| Night standby loss | ≤10 mA | ||
| Working temperature range | -25℃ ~ +60℃ | ||
| Permitted ambient humidity | 0%~98% no condensation | ||
| Communication port | RS485(optional) | ||
| External overview | |||
| Wiring terminals | TC series barrier type wiring | ||
| Display method | LED [128*68dot matrix,white backlight] | ||
| Display language | English | ||
| Protection level | IP20 [indoor] | ||
| Noise | <30 dBA | ||
| Installation method | Cabinet type | ||
| External dimensions[width depth height] | 450 *550 *760[mm](subject to actual dimensions) | ||
| Net weight | 85KG(subject to actual weight) |

Drawer Type PV Charge Controller, 30A to 150A
Drawer type PV charge controller from 30A to 150A
Performance Features
1. The solar charge controller adopts industrial-grade chips to ensure the stable feature of controller
2. Excellent EMC design
3. High efficient PWM charging technology which has three charging stages (buck charging stage, equalize charging stage and float charging stage), and improves battery storage efficiency and charging efficiency.
4. Advanced battery activation technology which increases battery lifetime 30% at least and improves the system performance
5. The 30A to 300A solar charge controller adopts imported IGBT power module or MOSFET as electronic switch which can improve the stable performance of controller. There aren’t any mechanical switches in the system
6. LCD will display the system status and working parameters
7. Parameters setting flexibly
8. Users can parallel connect lots of the controller is a system
9. Fully enclosed duct design and high speed fan for cooling making the controller working in a variety of harsh environments
10. DC output function (Optional)
11. Standard Modbus protocol for RS-485 communication to extend the communication distance (Optional)
12. The solar charge controller will alarm when the system status is abnormal
13. New SOC method displays battery power accurately
14. With power generation statistics function to facilitate the view of power generation of daily, month and total
15. There is temperature compensation function which will compensate the temperature according to different battery type
16. The solar charge controller adopts graphical dot-matrix LCD and 4 buttons as HMI for full menu and easy operation
17. RTC time function
Parameters of 150A to 300A solar charger controller
Above parameter only for reference ,could be custom made to user specifications
| System voltage LCS-SCC-08 | 24V | 48V | 96V | 192V | 240V | 360V | 480V | 540V | 600V |
| Max. VOC of PV arrays | 100V | 100V | 200V | 350V | 450V | 700V | 950V | 1000V | 1000V |
| Rated charging current | √30A √50A √60A √80A √100A √120A √150A | ||||||||
| Equalize charging point | 28.8V | 57.6V | 115.2V | 230.4V | 288V | 432V | 576V | 648V | 720V |
| Equalize charging recovery point | 26.4V | 52.8V | 105.6V | 211.2V | 264V | 396V | 528V | 594V | 660V |
| Equalize charging time | 120 minutes (default setting) | ||||||||
| Float charging point | 27.6V | 55.2V | 110.4V | 220.8V | 276V | 414V | 552V | 621V | 590V |
| Over voltage point | 32V | 64V | 128V | 256V | 320V | 480V | 640V | 720V | 800V |
| Over voltage recovery point | 30V | 60V | 120V | 240V | 300V | 450V | 600V | 675V | 750V |
| Standy-by consumption | <0.5W | ||||||||
| Display | 3'' LCD | ||||||||
| Display language | English | ||||||||
| Terminal typy | TC series barrier terminal | ||||||||
| Elevation | <4000 meter, should reduce power if the elevation high than 4000 meter | ||||||||
| Humidity | 0~98%, non-condesing | ||||||||
| Protection level | IP32 | ||||||||
| Noise | <30dBA | ||||||||
| Cooling method | High speed fan + heat sink | ||||||||
| Environment temperature | -25°c~55°c | ||||||||
| Dimension | 420*345*157 | ||||||||
| Net Weight | 12KG |


Solar Charge Controller for 96V to 600VDC Battery Systems, 30A to 150A
96V-600V DC battery system 30A-150A solar charge controller
Performance Features
1. The solar charge controller adopts industrial-grade chips to ensure the stable feature of controller
2. Excellent EMC design
3. High efficient PWM charging technology which has three charging stages (buck charging stage, equalize charging stage and float charging stage), and improves battery storage efficiency and charging efficiency.
4. Advanced battery activation technology which increases battery lifetime 30% at least and improves the system performance
5. The 30A to 300A solar charge controller adopts imported IGBT power module or MOSFET as electronic switch which can improve the stable performance of controller. There aren’t any mechanical switches in the system
6. LCD will display the system status and working parameters
7. Parameters setting flexibly
8. Users can parallel connect lots of the controller is a system
9. Fully enclosed duct design and high speed fan for cooling making the controller working in a variety of harsh environments
10. DC output function (Optional)
11. Standard Modbus protocol for RS-485 communication to extend the communication distance (Optional)
12. The solar charge controller will alarm when the system status is abnormal
13. New SOC method displays battery power accurately
14. With power generation statistics function to facilitate the view of power generation of daily, month and total
15. There is temperature compensation function which will compensate the temperature according to different battery type
16. The solar charge controller adopts graphical dot-matrix LCD and 4 buttons as HMI for full menu and easy operation
17. RTC time function
Parameters of 150A to 300A solar charger controller
Above parameter only for reference ,could be custom made to user specifications
| System voltage LCS-SCC-09 | 24V | 48V | 96V | 192V | 240V | 360V | 480V | 540V | 600V |
| Max. VOC of PV arrays | 100V | 100V | 200V | 350V | 450V | 700V | 950V | 1000V | 1000V |
| Rated charging current | √30A √50A √60A √80A √100A √120A √150A | ||||||||
| Equalize charging point | 28.8V | 57.6V | 115.2V | 230.4V | 288V | 432V | 576V | 648V | 720V |
| Equalize charging recovery point | 26.4V | 52.8V | 105.6V | 211.2V | 264V | 396V | 528V | 594V | 660V |
| Equalize charging time | 120 minutes (default setting) | ||||||||
| Float charging point | 27.6V | 55.2V | 110.4V | 220.8V | 276V | 414V | 552V | 621V | 590V |
| Over voltage point | 32V | 64V | 128V | 256V | 320V | 480V | 640V | 720V | 800V |
| Over voltage recovery point | 30V | 60V | 120V | 240V | 300V | 450V | 600V | 675V | 750V |
| Standy-by consumption | <0.5W | ||||||||
| Display | 3'' LCD | ||||||||
| Display language | English | ||||||||
| Terminal typy | TC series barrier terminal | ||||||||
| Elevation | <4000 meter, should reduce power if the elevation high than 4000 meter | ||||||||
| Humidity | 0~98%, non-condesing | ||||||||
| Protection level | IP32 | ||||||||
| Noise | <30dBA | ||||||||
| Cooling method | High speed fan + heat sink | ||||||||
| Environment temperature | -25°c~55°c | ||||||||
| Dimension | 420*345*157 | ||||||||
| Net Weight | 12KG |
Big Current PV Charge Controller, 150A to 300A
150A-300A Big current PV charge controller
Performance Features
1. The solar charge controller adopts industrial-grade chips to ensure the stable feature of controller
2. Excellent EMC design
3. High efficient PWM charging technology which has three charging stages (buck charging stage, equalize charging stage and float charging stage), and improves battery storage efficiency and charging efficiency.
4. Advanced battery activation technology which increases battery lifetime 30% at least and improves the system performance
5. The 30A to 300A solar charge controller adopts imported IGBT power module or MOSFET as electronic switch which can improve the stable performance of controller. There aren’t any mechanical switches in the system
6. LCD will display the system status and working parameters
7. Parameters setting flexibly
8. Users can parallel connect lots of the controller is a system
9. Fully enclosed duct design and high speed fan for cooling making the controller working in a variety of harsh environments
10. DC output function (Optional)
11. Standard Modbus protocol for RS-485 communication to extend the communication distance (Optional)
12. The solar charge controller will alarm when the system status is abnormal
13. New SOC method displays battery power accurately
14. With power generation statistics function to facilitate the view of power generation of daily, month and total
15. There is temperature compensation function which will compensate the temperature according to different battery type
16. The solar charge controller adopts graphical dot-matrix LCD and 4 buttons as HMI for full menu and easy operation
17. RTC time function
Parameters of 150A to 300A solar charger controller
Above parameter only for reference ,could be custom made to user specifications
| System voltage LCS-SCC-10 | 24V | 48V | 96V | 192V | 240V | 360V | 480V | 540V | 600V |
| Max. VOC of PV arrays | 100V | 100V | 200V | 350V | 450V | 700V | 950V | 1000V | 1000V |
| Rated charging current | √150A √200A √250A √300A √350A √400A | ||||||||
| Equalize charging point | 28.8V | 57.6V | 115.2V | 230.4V | 288V | 432V | 576V | 648V | 720V |
| Equalize charging recovery point | 26.4V | 52.8V | 105.6V | 211.2V | 264V | 396V | 528V | 594V | 660V |
| Equalize charging time | 120 minutes (default setting) | ||||||||
| Float charging point | 27.6V | 55.2V | 110.4V | 220.8V | 276V | 414V | 552V | 621V | 590V |
| Over voltage point | 32V | 64V | 128V | 256V | 320V | 480V | 640V | 720V | 800V |
| Over voltage recovery point | 30V | 60V | 120V | 240V | 300V | 450V | 600V | 675V | 750V |
| Standy-by consumption | <0.5w< span=""> | ||||||||
| Display | 3'' LCD | ||||||||
| Display language | English | ||||||||
| Terminal typy | TC series barrier terminal | ||||||||
| Elevation | |||||||||
| Humidity | 0~98%, non-condesing | ||||||||
| Protection level | IP32 | ||||||||
| Noise | <30dba< span=""> | ||||||||
| Cooling method | High speed fan + heat sink | ||||||||
| Environment temperature | -25°c~55°c | ||||||||
| Dimension | 900*520*500 | ||||||||
| Net Weight | 75KG |
480V Station Type PV Charge Controller, 30A, 50A and 100A
This model appears in the source solar charge controller list. Its product page returned a 404 error on every route tried, including encoded slash variants, so no description, specification table or photograph could be verified for it. It is listed here for completeness and can be quoted on request once verified details are available.
380V Solar Controller, 50A, 80A and 100A
This model appears in the source solar charge controller list. Its product page returned a 404 error on every route tried, including encoded slash variants, so no description, specification table or photograph could be verified for it. It is listed here for completeness and can be quoted on request once verified details are available.
240V Equalize and Float Charge Controller, 30A to 150A
This model appears in the source solar charge controller list. Its product page returned a 404 error on every route tried, including encoded slash variants, so no description, specification table or photograph could be verified for it. It is listed here for completeness and can be quoted on request once verified details are available.
Wind Power Controllers
Wind and wind solar hybrid controllers with PWM constant voltage control and three phase dump load protection for safe operation in strong wind.
Wind Solar Hybrid Controller
Large screen LCD display shows wind turbine, solar panel, battery and controller working status at a glance, including wind turbine voltage, current and power, solar voltage, current and power, and battery voltage, charging current, charging power and capacity.
Uses two control systems: a PWM constant voltage system plus a three phase dump load system.
PWM constant voltage control is 120 percent of the rated power of the wind turbine. When the PWM constant voltage power range is exceeded, the three phase dump load starts immediately to ensure the safe operation of the whole wind turbine system.
When the battery is disconnected or damaged, the three phase dump load starts automatically, preventing wind turbine idling and runaway accidents.
PWM control ensures constant voltage and constant current charging of the battery by the wind turbine in strong wind conditions.
Battery reverse connection protection, battery disconnection protection and battery damage protection.
Battery overcharge protection. When the battery is full (battery voltage reaches 125 percent of rated voltage), the controller automatically applies three phase dump load and stops charging the battery.
Battery automatic recovery charging function. When battery voltage drops to 108 percent of rated voltage, the dump load stops and charging automatically resumes.
According to the type of wind turbine, mechanical yaw control, mechanical tail folding control, and mechanical, hydraulic, pneumatic, electromagnetic and other braking control functions can be added.
A lightning arrester is installed inside the controller, limiting transient overvoltage on the wind turbine power line to within the range the equipment or system can withstand, or conducting strong lightning current to earth, protecting equipment from lightning damage.
The controller has a manual three phase dump load switch that the user can use as circumstances require; using this switch forcibly applies three phase dump load to the wind turbine.
Optional remote monitoring functions including RS232, RS485, GPRS, USB and RJ45 communication methods, which can monitor multiple devices at the same time.
Optional temperature compensation.
| SpecificationBW | 5KW-48Vdc | 5KW-120Vdc | 5KW-192Vdc |
| Wind turbine rated power | 5KW | 5KW | 5KW |
| Wind turbine maximum power | 10KW | 10KW | 10KW |
| * Solar panel power | 1.5KWp | 1.5KWp | 1.5KWp |
| Battery rated voltage | 48Vdc | 120Vdc | 192Vdc |
| Function | Rectification, charging, control, DC output (optional) | ||
| Automatic protection functions | Overvoltage protection, constant voltage charging, lightning arrester | ||
| Manual function | Wind turbine manual brake | ||
| Display | LCD display plus LED | ||
| Display content | Wind turbine voltage, current and power; solar panel voltage, current and power; battery voltage and charging current | ||
| PWM constant voltage | >58Vdc | >145Vdc | >232 Vdc |
| Wind turbine three phase dump load operating voltage | 60 ± 1Vdc | 150 ± 2Vdc | 240 ± 5Vdc |
| Wind turbine resume charging voltage | 54 ± 1Vdc | 135 ± 2Vdc | 216 ± 5Vdc |
| *Solar stop charging voltage | 60 ± 1Vdc | 150 ± 2Vdc | 240 ± 5Vdc |
| *Solar resume charging voltage | 54 ± 1Vdc | 135 ± 2Vdc | 216 ± 5Vdc |
| User supplied battery connection cable | >20mm ² | >10mm ² | >6mm ² |
| PWM fuse | 125A | 50A | 32A |
| * Solar fuse | 40A | 16A | 10A |
| Charging fuse | 160A | 63A | 40A |
| Working temperature | -30-60 ° C | ||
| Relative humidity | < 90% no condensation | ||
| Noise (1m) | < 40dB | ||
| Protection level | IP20 (indoor Indoor ) IP65 ( outdoor Outdoors) | ||
| Cooling method | Forced air cooling | ||
| * Remote communication (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||
| * Temperature compensation (optional) | -4mv/ ° C/2V,-35 ° C~+80 ° C, Accuracy Accuracy: ± 1 ° C | ||
| Controller dimensions / weight | 580*400*240mm 23Kg | 510*360*240mm 17Kg | 510*360*240mm 17Kg |
| Dump load dimensions / weight | 600*450*380mm 28Kg | 600*450*380mm 28Kg | 600*450*380mm 28Kg |
Wind Grid Tie Controller
Uses two control systems: a PWM constant voltage system plus a three phase dump load system.
PWM constant voltage control is 120 percent of the rated power of the wind turbine. When the PWM constant voltage power range is exceeded, the three phase dump load starts automatically, runs for 10 to 20 minutes, then stops, the wind turbine restarts and power supply output resumes, ensuring safe operation of the whole wind turbine system.
In strong wind conditions, the controller outputs constant voltage and provides a DC constant voltage power supply to ensure normal operation of the inverter.
When the grid connected inverter is offline, the controller outputs constant voltage and waits for the inverter to resume work.
When the power grid is off, the controller three phase dump load starts automatically and the inverter stops output to the grid. When grid power resumes, the controller stops dump load and the inverter resumes power supply.
According to the type of wind turbine, mechanical yaw, tail folding, and mechanical, hydraulic, pneumatic or electromagnetic brake functions can be added.
A lightning arrester is installed inside the controller to protect equipment from lightning damage.
LED status indication on the front panel for wind turbine, dump load, stop delay, undervoltage and grid power, plus DC output voltage indication.
Voltmeter indication shows the controller DC output voltage.
The controller has an emergency stop switch; in an emergency, pressing the front panel emergency stop button cuts all controller power and the wind turbine immediately applies three phase dump load.
The controller has a manual three phase dump load switch that the user can use as circumstances require.
| Model | 10KW | 20KW |
| Function | Rectification, control | |
| Working environment | Temperature-10-40℃,humidity≤80% | |
| PWM constant voltage | ≥480Vdc | ≥480Vdc |
| Wind turbine three phase dump load1operating voltage | 560±5Vdc | 560±5Vdc |
| Wind turbine three phase dump load2operating voltage | ---- | 570±5Vdc |
| Wind turbine three phase dump loaddelay | 12-20minutes | 12-20minutes |
| Undervoltage indication | ≤200Vdc | ≤200Vdc |
| PWM fuse | 32A | 63A |
| DC output fuse | 40A | 80A |
| Controller dimensions | 570*550*330 mm | 570*550*330 mm |
| Controller weight | 27 Kg | 30 Kg |
| Dump load dimensions | 770*550*460 mm | 810*580*980 mm |
| Dump load weight | 35 Kg | 77 Kg |
High Power Wind Controller with Three Phase Dump Load
Large screen LCD display shows wind turbine, solar panel, battery and controller working status at a glance, including wind turbine voltage, current and power, solar voltage, current and power, and battery voltage, charging current, charging power and capacity.
Uses two control systems: a PWM constant voltage system plus a three phase dump load system.
PWM constant voltage control is 120 percent of the rated power of the wind turbine. When the PWM constant voltage power range is exceeded, the three phase dump load starts immediately to ensure the safe operation of the whole wind turbine system.
When the battery is disconnected or damaged, the three phase dump load starts automatically, preventing wind turbine idling and runaway accidents.
PWM control ensures constant voltage and constant current charging of the battery by the wind turbine in strong wind conditions.
Battery reverse connection protection, battery disconnection protection and battery damage protection.
Battery overcharge protection. When the battery is full (battery voltage reaches 125 percent of rated voltage), the controller automatically applies three phase dump load and stops charging the battery.
Battery automatic recovery charging function. When battery voltage drops to 108 percent of rated voltage, the dump load stops and charging automatically resumes.
According to the type of wind turbine, mechanical yaw control, mechanical tail folding control, and mechanical, hydraulic, pneumatic, electromagnetic and other braking control functions can be added.
A lightning arrester is installed inside the controller, limiting transient overvoltage on the wind turbine power line to within the range the equipment or system can withstand, or conducting strong lightning current to earth, protecting equipment from lightning damage.
The controller has a manual three phase dump load switch that the user can use as circumstances require; using this switch forcibly applies three phase dump load to the wind turbine.
Optional remote monitoring functions including RS232, RS485, GPRS, USB and RJ45 communication methods, which can monitor multiple devices at the same time.
Optional temperature compensation.
| Specification LCS-WCC-03 | 26KW-420Vdc | 39KW-420Vdc | 65KW-420Vdc |
| Wind turbine rated power | 20KW | 30KW | 50KW |
| Wind turbine maximum power | 40KW | 50KW | 80KW |
| Solar panel power | 6KW | 9KW | 15KW |
| Battery rated voltage | 420Vdc | 420Vdc | 420Vdc |
| Function | Rectification, charging, control | ||
| Display | LCD display | ||
| Display content | Wind turbine voltage, wind turbine current, wind turbine power, solar panel voltage, solar panel current, solar panel power, battery voltage, charging current | ||
| PWM constant voltage | > 507Vdc | > 507Vdc | > 507Vdc |
| Wind turbine three phase dump load 1 operating voltage | 520±5Vdc | 520±5Vdc | 515±5Vdc |
| Wind turbine three phase dump load 2 operating voltage | 525±5Vdc | 525±5Vdc | 520±5Vdc |
| Wind turbine three phase dump load 3 operating voltage | -------------- | ------------- | 525±5Vdc |
| Wind turbine resume charging voltage | 475±5Vdc | 475±5Vdc | 475±5Vdc |
| Solar stop charging voltage | 520±5Vdc | 520±5Vdc | 520±5Vdc |
| Solar resume charging voltage | < 507Vdc | < 507Vdc | < 507Vdc |
| Battery undervoltage indication | 350±5Vdc | 350±5Vdc | 350±5Vdc |
| User supplied three phase dump load connection cable | > 6mm² | > 10mm² | > 16mm² |
| User supplied battery connection cable | > 12mm² | > 20mm² | > 30mm² |
| PWM fuse | |||
| Solar fuse | |||
| Charging fuse | |||
| Working temperature | -30 | ||
| Relative humidity | < 90% no condensation | ||
| Noise (1m) | < 40dB | ||
| Protection level | IP20 (indoor) | ||
| Cooling method | Forced air cooling | ||
| * Remote communication (optional) | RS485/USB/GPRS/Ethernet | ||
| * Temperature compensation (optional) | -4mv/ °C / 2V,~+, Accuracy : ± 1°C | ||
| Controller dimensions (mm) | 500*500*900 | 500*500*900 | 690*590*1300 |
| Controller weight | |||
| Dump load dimensions (mm) | 690*450*1000 | 690*450*1000 690*450*530 | 690*450*1000 690*450*1000 |
| Dump load weight |

19KW Wind Solar Hybrid Controller
Product Characteristic
◆The big screen LCD display. Clearly present the working status of the wind turbine, solar panel, battery and controller.(Wind turbine voltage, current, power display ;solar voltage, current, power display, battery charging current, voltage, charging power, power display.)
◆Two sets of control systems:PWM constant voltage system and three-phase dump load system.
◆PWM constant voltage control is 120% of the rated power of the wind turbine . In case exceeding of PWM’s capacity, the three-phase dump load will automatically start immediately to ensure safe running of the overall wind turbine system.
◆Under the circumstances of disconnecting or damage of the battery, the three-phase dump load will start automatically to avoid the idling for wind turbine and the occurrence of runaway accident.
◆Under the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.
◆The protection function of reverse connection, disconnection and damage-resisting of the battery will be applied.
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the rated voltage), the controller will carry out three-phase dump load automatically to stop charging the battery.
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-phase dump load to recharge battery automatically.
◆For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.
◆Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
Technical Parameters
Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power.
| Model | LCS-WCC-04 1.9KW | |
| Wind power | 1.5KW | |
| Solar panel power | 900W | |
| Battery | 24Vdc | 48Vdc |
| Function | Charge, control | |
| Operating environment | Temperature -10-40℃,humidity≤80% | |
| PWM constant pressure voltage | >28Vdc | >280 Vdc |
| 3-phase load voltage of the wind turbine | 29±2Vdc | 290±5Vdc |
| Recovery charging voltage of the wind turbine | 27±2Vdc | 280±5Vdc |
| Solar controller stop charging voltage | 29±2Vdc | 290±5Vdc |
| Solar restore charge voltage | 27±2Vdc | 280±5Vdc |
| Low-voltage of the battery | 20±2Vdc | 200±5Vdc |
| Self-provided connecting wire of the battery | >12mm² | >6mm² |
| PWM fuse | 63A | 40A |
| Solar fuse | 32A | 16A |
| Charging fuse | 125A | 32A |
| Size of the controller | 590*490*315 mm | 590*490*315 mm |
| Weight of the controller | 15 Kg | 16 Kg |
| Size of the load | 490*460*310 mm | 490*460*310 mm |
| Weight of the load | 15.5 Kg | 15.5 Kg |


26KW Wind Solar System Hybrid Controller
Product Characteristic
◆The big screen LCD display. Clearly present the working status of the wind turbine, solar panel,
battery and controller.(Wind turbine voltage, current, power display ;solar voltage, current, power
display, battery charging current, voltage, charging power, power display.)
◆Two sets of control systems: PWM constant voltage system and three-phase dump load system.
◆PWM constant voltage control is 120% of the rated power of the wind turbine . In case exceeding of
PWM’s capacity, the three-phase dump load will automatically start immediately to ensure safe running
of the overall wind turbine system.
◆Under the circumstances of disconnecting or damage of the battery, the three-phase dump load will start
automatically to avoid the idling for wind turbine and the occurrence of runaway accident.
◆Under the strong or super-strong wind conditions PWM control to ensure battery charged by the wind
turbine with constant voltage and current.
◆The protection function of reverse connection, disconnection and damage-resisting of the battery will be
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the
rated voltage), the controller will carry out three-phase dump load automatically to stop charging the
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-
phase dump load to recharge battery automatically.
◆For the different wind turbine type, the controller can be equipped with mechanical yawing, furled
empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine
under the bearable voltage of the equipment or system. On the other way, to conduct the strong
lightening current into the earth directly to avoid any damage of equipment.
◆Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind
turbine will carry out three-phase dump load forcibly.
◆ Optional communication Mode:RS232、RS485、GPRS、USB、RJ45 ect, Can monitor multiple
devices running.
Technical Parameters
Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Model | LCS-WCC-05 2.6KW | ||
| Wind power | 2KW | 2KW | 2KW |
| Solar panel power | 600W | 600W | 600W |
| Battery voltage | 24Vdc | 48Vdc | 96Vdc |
| Function | Charge, control | ||
| Operating environment | Temperature -30-60℃,humidity≤80% | ||
| PWM constant pressure voltage | >28Vdc | >56Vdc | >110Vdc |
| 3-phase load voltage of the wind turbine | 29±1Vdc | 58±1Vdc | 116±2Vdc |
| Recovery charging voltage of the wind turbine | 27±1Vdc | 54±1Vdc | 108±2Vdc |
| Solar controller stop charging voltage | 29±1Vdc | 58±1Vdc | 116±2Vdc |
| Solar restore charge voltage | 27±1Vdc | 54±1Vdc | 108±2Vdc |
| Low-voltage of the battery | 20±1Vdc | 40±1Vdc | 80±2Vdc |
| Self-provided connecting wire of the battery | >20mm² | >10mm² | >24mm² |
| PWM fuse | 100A | 40A | 20A |
| Solar fuse | 32A | 16A | 10A |
| Charging fuse | 125A | 63A | 32A |
| Size of the controller | 590*490*315 mm | 500*440*290 mm | 500*440*290 mm |
| Weight of the controller | 23 Kg | 15 Kg | 16 Kg |
| Size of the load | 490*460*310 mm | 490*460*310 mm | 490*460*310mm |
| Weight of the load | 15.5 Kg | 15.5 Kg | 15.5Kg |
39KW Wind Solar Hybrid Controller
Product Characteristic
◆The big screen LCD display. Clearly present the working status of the wind turbine, solar panel, battery and controller.(Wind turbine voltage, current, power display ;solar voltage, current, power display, battery charging current, voltage, charging power, power display.)
◆Two sets of control systems:PWM constant voltage system and three-phase dump load system.
◆PWM constant voltage control is 120% of the rated power of the wind turbine . In case exceeding of PWM’s capacity, the three-phase dump load will automatically start immediately to ensure safe running of the overall wind turbine system.
◆Under the circumstances of disconnecting or damage of the battery, the three-phase dump load will start automatically to avoid the idling for wind turbine and the occurrence of runaway accident.
◆Under the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.
◆The protection function of reverse connection, disconnection and damage-resisting of the battery will be applied.
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the rated voltage), the controller will carry out three-phase dump load automatically to stop charging the battery.
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-phase dump load to recharge battery automatically.
◆For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.
◆Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
◆ Optional communication Mode:RS232、RS485、GPRS、USB、RJ45 ect, Can monitor multiple devices running.
Technical Parameters
Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Model | LCS-WCC-06 3.9KW | ||
| Wind power | 3KW | 3KW | 3KW |
| Solar panel power | 900W | 900W | 900W |
| Battery voltage | 48Vdc | 96Vdc | 120Vdc |
| Function | Charge, control | ||
| Operating environment | Temperature -30-60℃,humidity≤80% | ||
| PWM constant pressure voltage | >56Vdc | >110Vdc | >135Vdc |
| 3-phase load voltage of the wind turbine | 58±1Vdc | 58±1Vdc | 145±2Vdc |
| Recovery charging voltage of the wind turbine | 54±1Vdc | 54±1Vdc | 135±2Vdc |
| Solar controller stop charging voltage | 58±1Vdc | 58±1Vdc | 145±2Vdc |
| Solar restore charge voltage | 54±1Vdc | 54±1Vdc | 135±2Vdc |
| Low-voltage of the battery | 40±1Vdc | 40±1Vdc | 100±2Vdc |
| Self-provided connecting wire of the battery | >12mm² | >10mm² | >24mm² |
| PWM fuse | 80A | 40A | 20A |
| Solar fuse | 20A | 16A | 10A |
| Charging fuse | 100A | 63A | 32A |
| Size of the controller | 550*400*230 mm | ||
| Weight of the controller | 21 Kg | ||
| Size of the load | 660*510*450 mm | ||
| Weight of the load | 31 Kg |
65KW Wind Solar Off Grid Hybrid Controller
Product Characteristic
◆The big screen LCD display. Clearly present the working status of the wind turbine, solar panel, battery and controller.(Wind turbine voltage, current, power display ;solar voltage, current, power display, battery charging current, voltage, charging power, power display.)
◆Two sets of control systems:PWM constant voltage system and three-phase dump load system.
◆PWM constant voltage control is 120% of the rated power of the wind turbine . In case exceeding of PWM’s capacity, the three-phase dump load will automatically start immediately to ensure safe running of the overall wind turbine system.
◆Under the circumstances of disconnecting or damage of the battery, the three-phase dump load will start automatically to avoid the idling for wind turbine and the occurrence of runaway accident.
◆Under the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.
◆The protection function of reverse connection, disconnection and damage-resisting of the battery will be applied.
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the rated voltage), the controller will carry out three-phase dump load automatically to stop charging the battery.
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-phase dump load to recharge battery automatically.
◆For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.
◆Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
◆ Optional communication Mode:RS232、RS485、GPRS、USB、RJ45 ect, Can monitor multiple devices running.
Technical Parameters
Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power.
| Model | LCS-WCC-07 6.5KW-48Vdc |
| Wind power | 5KW |
| Solar panel power | 1.5KW |
| Battery | 48Vdc |
| Function | Charge, control |
| Operating environment | Temperature -10-40℃,humidity≤80% |
| PWM constant pressure voltage | >56Vdc |
| 3-phase load voltage of the wind turbine | 58±1Vdc |
| Recovery charging voltage of the wind turbine | 54±1Vdc |
| Solar controller stop charging voltage | 58±1Vdc |
| Solar restore charge voltage | 54±1Vdc |
| Low-voltage of the battery | 40±1Vdc |
| Self-provided connecting wire of the battery | >20mm² |
| PWM fuse | 125A |
| Solar fuse | 32A |
| Charging fuse | 160A |
| Size of the controller | 550*400*230 mm |
| Weight of the controller | 23Kg |
| Size of the load | 660*510*450 mm |
| Weight of the load | 31 Kg |
| Type | 6.5KW-120Vdc | 6.5KW-240Vdc |
| Wind power | 5KW | 5KW |
| Solar panel power | 1.5KW | 1.5KW |
| Battery | 120Vdc | 240Vdc |
| Function | Charge, control | |
| Operating environment | Temperature -10-40℃,humidity≤80% | |
| PWM constant pressure voltage | >135Vdc | >280 Vdc |
| 3-phase load voltage of the wind turbine | 145±2Vdc | 290±5Vdc |
| Recovery charging voltage of the wind turbine | 135±2Vdc | 280±5Vdc |
| Solar controller stop charging voltage | 145±2Vdc | 290±5Vdc |
| Solar restore charge voltage | 135±2Vdc | 280±5Vdc |
| Low-voltage of the battery | 100±2Vdc | 200±5Vdc |
| Self-provided connecting wire of the battery | >10mm² | >6mm² |
| PWM fuse | 63A | 40A |
| Solar fuse | 16A | 10A |
| Charging fuse | 63A | 50A |
| Size of the controller | 500*440*290 mm | 500*440*290 mm |
| Weight of the controller | 21 Kg | 21 Kg |
| Size of the load | 660*510*450 mm | 660*510*450 mm |
| Weight of the load | 31 Kg | 31 Kg |
13KW Off Grid System Wind Solar Hybrid Controller
Product Characteristic
◆The big screen LCD display. Clearly present the working status of the wind turbine, solar panel, battery and controller.(Wind turbine voltage, current, power display ;solar voltage, current, power display, battery charging current, voltage, charging power, power display.)
◆Two sets of control systems:PWM constant voltage system and three-phase dump load system.
◆PWM constant voltage control is 120% of the rated power of the wind turbine . In case exceeding of PWM’s capacity, the three-phase dump load will automatically start immediately to ensure safe running of the overall wind turbine system.
◆Under the circumstances of disconnecting or damage of the battery, the three-phase dump load will start automatically to avoid the idling for wind turbine and the occurrence of runaway accident.
◆Under the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.
◆The protection function of reverse connection, disconnection and damage-resisting of the battery will be applied.
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the rated voltage), the controller will carry out three-phase dump load automatically to stop charging the battery.
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-phase dump load to recharge battery automatically.
◆For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.
◆Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
◆ Optional communication Mode:RS232、RS485、GPRS、USB、RJ45 ect, Can monitor multiple devices running.
Technical Parameters
※ Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Type | LCS-WCC-08 13KW-120Vdc |
| Wind power | 10KW |
| Solar panel power | 3KW |
| Battery | 120Vdc |
| Function | Charge, control |
| Operating environment | Temperature -30-60℃,humidity≤80% |
| PWM constant pressure voltage | >138Vdc |
| 3-phase load voltage of the wind turbine | 145±2Vdc |
| Recovery charging voltage of the wind turbine | 135±2Vdc |
| Solar controller stop charging voltage | 145±2Vdc |
| Solar restore charge voltage | 135±2Vdc |
| Low-voltage of the battery | 100±2Vdc |
| Self-provided connecting wire of the battery | >12mm² |
| PWM fuse | 80A |
| Solar fuse | 25A |
| Charging fuse | 125A |
| Size of the controller | 550*400*230 mm |
| Weight of the controller | 21Kg |
| Size of the load | 760*510*430 mm |
| Weight of the load | 34 Kg |
26KW Wind Solar Hybrid Controller
LCS-WCC-09 Wind-Solar Hybrid Controller
Product Characteristic
◆The big screen LCD display. Clearly present the working status of the wind turbine, solar panel, battery and controller.(Wind turbine voltage, current, power display ;solar voltage, current, power display, battery charging current, voltage, charging power, power display.)
◆Two sets of control systems:PWM constant voltage system and three-phase dump load system.
◆PWM constant voltage control is 120% of the rated power of the wind turbine . In case exceeding of PWM’s capacity, the three-phase dump load will automatically start immediately to ensure safe running of the overall wind turbine system.
◆Under the circumstances of disconnecting or damage of the battery, the three-phase dump load will start automatically to avoid the idling for wind turbine and the occurrence of runaway accident.
◆Under the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.
◆The protection function of reverse connection, disconnection and damage-resisting of the battery will be applied.
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the rated voltage), the controller will carry out three-phase dump load automatically to stop charging the battery.
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-phase dump load to recharge battery automatically.
◆For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.
◆Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
◆ Optional communication Mode:RS232、RS485、GPRS、USB、RJ45 ect, Can monitor multiple devices running.
Technical Parameters
Above parameter only for reference
1.Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Model | LCS-WCC-09 26KW-360Vdc |
| Wind power | 20KW |
| Solar panel power | 6KW |
| Battery | 360Vdc |
| Function | Charge, control |
| Operating environment | Temperature -30-60℃,humidity≤80% |
| PWM constant pressure voltage | >420Vdc |
| 3-phase load voltage of the wind turbine | 435±5Vdc |
| Recovery charging voltage of the wind turbine | 405±5Vdc |
| Solar controller stop charging voltage | 435±5Vdc |
| Solar restore charge voltage | 405±5Vdc |
| Low-voltage of the battery | 300±5Vdc |
| Self-provided connecting wire of the battery | >12mm² |
| PWM fuse | 40A |
| Solar fuse | 20A |
| Charging fuse | 80A |
| Size of the controller | 560*460*950 mm |
| Weight of the controller | 53 Kg |
| Size of the load | 810*580*980mm |
| Weight of the load | 77Kg |
39KW Wind Solar Hybrid System Off Grid Controller
Product Characteristic
◆The big screen LCD display. Clearly present the working status of the wind turbine, solar panel, battery and controller.(Wind turbine voltage, current, power display ;solar voltage, current, power display, battery charging current, voltage, charging power, power display.)
◆Two sets of control systems:PWM constant voltage system and three-phase dump load system.
◆PWM constant voltage control is 120% of the rated power of the wind turbine . In case exceeding of PWM’s capacity, the three-phase dump load will automatically start immediately to ensure safe running of the overall wind turbine system.
◆Under the circumstances of disconnecting or damage of the battery, the three-phase dump load will start automatically to avoid the idling for wind turbine and the occurrence of runaway accident.
◆Under the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.
◆The protection function of reverse connection, disconnection and damage-resisting of the battery will be applied.
◆Over-charging protection of the battery: When the battery is full (the battery voltage getting 125% of the rated voltage), the controller will carry out three-phase dump load automatically to stop charging the battery.
◆Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage, it stops three-phase dump load to recharge battery automatically.
◆For the different wind turbine type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
◆The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.
◆Ammeter and voltmeter indication: Indicate the charging current and voltage of the battery.
◆The controller is equipped with manual three-phase dump load switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.
◆ Optional communication Mode:RS232、RS485、GPRS、USB、RJ45 ect, Can monitor multiple devices running.
Technical Parameters
Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Type | LCS-WCC-10 39KW-500Vdc |
| Wind power | 30KW |
| Solar panel power | 9KW |
| Battery | 500Vdc |
| Function | Charge, control |
| Operating environment | Temperature -30-60℃,humidity≤80% |
| PWM constant pressure voltage | >588Vdc |
| 3-phase load voltage of the wind turbine | 610±5Vdc |
| Recovery charging voltage of the wind turbine | 567±5Vdc |
| Solar controller stop charging voltage | 610±5Vdc |
| Solar restore charge voltage | 610±5Vdc |
| Low-voltage of the battery | 420±5Vdc |
| Self-provided connecting wire of the battery | >12mm² |
| PWM fuse | 63A |
| Solar fuse | 20A |
| Charging fuse | 80A |
| Size of the controller | 560*460*950 mm |
| Weight of the controller | 51 Kg |
| Size of the load | 810*590*1405 mm |
| Weight of the load | 140 Kg |
39KW Wind Grid Tie System Controller
Product Characteristics
◆ Adopt two sets of control systems, PWM constant pressure system and three-phase load discharging system.
◆ PWM constant pressure control is 120% of the rated power of the wind turbine generator. In case of exceeding the scope of PWM constant pressure power, the three-phase load discharging will automatically start. After operation for 10-20 minutes, the three-phase load discharging will stop load discharging and the wind turbine generator will re-start to resume power supply, as a result, safe operation of the overall wind turbine generation system is ensured.
◆ Under the conditions of strong or super-strong wind, the controller will conduct constant pressure output and provide DC constant power supply to ensure normal operation of the inverter.
◆ Under the condition of disconnected grid-connected inverter, the controller will conduct constant pressure output to wait for inverter resumption.
◆ When the power grid is off, the three-phase load discharging of the controller will automatically start and the inverter will stop grid output. When the grid power resumes, the controller stops three-phase load discharging and the inverter will resume power supply.
◆ According to the category of the wind turbine generator, the controller can be additionally equipped with mechanical yawing, swing-tai, mechanical or hydraulic, pneumatic, magnetic and other brake functions.
◆ The inside of the controller is equipped with lightening protection device. Contain the transit over voltage penetrating into the wind turbine generator within the voltage scope bearable to the equipment or system or conduct the strong lightening current into the earth to avoid equipment damage posed by lightening impact.
◆ LED status indication: The frontal panel is equipped with indications of wind turbine generator, load discharging, stop delay time, under pressure, grid power and DC output voltage.
◆ Voltmeter indication: Indicate DC output voltage of the controller.
◆ The controller is equipped with emergency stop switch; in case of emergency, press down the emergency stop button in the front panel to cut off all power supply of the controller and the wind turbine generator will immediately carry out three-phase load discharging.
◆ The controller is equipped with manual three-phase load discharging switch; the user may use it according to actual circumstances. When using this switch, the wind turbine generator will forcibly carry out three-phase load discharging.
Technical Parameters
※ Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Model | LCS-WCC-11 3.9KW |
| Wind power | 3KW |
| Solar panel power | 900W |
| Function | rectifier ,control |
| Operating environment | Temperature -30-60℃,humidity≤80% |
| PWM constant pressure voltage | ≥380dc |
| 3-phase load voltage of the wind turbine | 410±5Vdc |
| Time-lapse of the wind turbine 3-phase load | 12-20 min |
| Low-valtage | ≤200Vdc |
| PWM Fuse | 10A |
| Solar Fuse | 3A |
| Fuse of DC output | 16A |
| Size of the controller | 480*360*240 mm |
| Weight of the controller | 18Kg |
| Size of the load | 660*320*320 mm |
| Weight of the load | 11 Kg |
65KW Wind Generator System Hybrid Controller
Product Characteristics
◆ Adopt two sets of control systems, PWM constant pressure system and three-phase load discharging system.
◆ PWM constant pressure control is 120% of the rated power of the wind turbine generator. In case of exceeding the scope of PWM constant pressure power, the three-phase load discharging will automatically start. After operation for 10-20 minutes, the three-phase load discharging will stop load discharging and the wind turbine generator will re-start to resume power supply, as a result, safe operation of the overall wind turbine generation system is ensured.
◆ Under the conditions of strong or super-strong wind, the controller will conduct constant pressure output and provide DC constant power supply to ensure normal operation of the inverter.
◆ Under the condition of disconnected grid-connected inverter, the controller will conduct constant pressure output to wait for inverter resumption.
◆ When the power grid is off, the three-phase load discharging of the controller will automatically start and the inverter will stop grid output. When the grid power resumes, the controller stops three-phase load discharging and the inverter will resume power supply.
◆ According to the category of the wind turbine generator, the controller can be additionally equipped with mechanical yawing, swing-tai, mechanical or hydraulic, pneumatic, magnetic and other brake functions.
◆ The inside of the controller is equipped with lightening protection device. Contain the transit over voltage penetrating into the wind turbine generator within the voltage scope bearable to the equipment or system or conduct the strong lightening current into the earth to avoid equipment damage posed by lightening impact.
◆ LED status indication: The frontal panel is equipped with indications of wind turbine generator, load discharging, stop delay time, under pressure, grid power and DC output voltage.
◆ Voltmeter indication: Indicate DC output voltage of the controller.
◆ The controller is equipped with emergency stop switch; in case of emergency, press down the emergency stop button in the front panel to cut off all power supply of the controller and the wind turbine generator will immediately carry out three-phase load discharging.
◆ The controller is equipped with manual three-phase load discharging switch; the user may use it according to actual circumstances. When using this switch, the wind turbine generator will forcibly carry out three-phase load discharging.
Technical Parameters
※ Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Model | LCS-WCC-12 6.5KW |
| Wind power | 5KW |
| Solar panel power | 1.5KW |
| Function | rectifier ,control |
| Operating environment | Temperature -30-60℃,humidity≤80% |
| PWM constant pressure voltage | ≥380Vdc |
| 3-phase load voltage of the wind turbine | 410±5Vdc |
| Time-lapse of the wind turbine 3-phase load | 12-20 min |
| Low-valtage | ≤200Vdc |
| PWM Fuse | 16A |
| Solar Fuse | 6A |
| Fuse of DC output | 20A |
| Size of the controller | 480*360*240mm |
| Weight of the controller | 18 Kg |
| Size of the load | 660*510*450mm |
| Weight of the load | 28.5 Kg |
13KW On Grid System Wind Turbine Controller
Product Characteristics
◆ Adopt two sets of control systems, PWM constant pressure system and three-phase load discharging system.
◆ PWM constant pressure control is 120% of the rated power of the wind turbine generator. In case of exceeding the scope of PWM constant pressure power, the three-phase load discharging will automatically start. After operation for 10-20 minutes, the three-phase load discharging will stop load discharging and the wind turbine generator will re-start to resume power supply, as a result, safe operation of the overall wind turbine generation system is ensured.
◆ Under the conditions of strong or super-strong wind, the controller will conduct constant pressure output and provide DC constant power supply to ensure normal operation of the inverter.
◆ Under the condition of disconnected grid-connected inverter, the controller will conduct constant pressure output to wait for inverter resumption.
◆ When the power grid is off, the three-phase load discharging of the controller will automatically start and the inverter will stop grid output. When the grid power resumes, the controller stops three-phase load discharging and the inverter will resume power supply.
◆ According to the category of the wind turbine generator, the controller can be additionally equipped with mechanical yawing, swing-tai, mechanical or hydraulic, pneumatic, magnetic and other brake functions.
◆ The inside of the controller is equipped with lightening protection device. Contain the transit over voltage penetrating into the wind turbine generator within the voltage scope bearable to the equipment or system or conduct the strong lightening current into the earth to avoid equipment damage posed by lightening impact.
◆ LED status indication: The frontal panel is equipped with indications of wind turbine generator, load discharging, stop delay time, under pressure, grid power and DC output voltage.
◆ Voltmeter indication: Indicate DC output voltage of the controller.
◆ The controller is equipped with emergency stop switch; in case of emergency, press down the emergency stop button in the front panel to cut off all power supply of the controller and the wind turbine generator will immediately carry out three-phase load discharging.
◆ The controller is equipped with manual three-phase load discharging switch; the user may use it according to actual circumstances. When using this switch, the wind turbine generator will forcibly carry out three-phase load discharging.
Technical Parameters
Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Model | LCS-WCC-13 13KW |
| Wind power | 10KW |
| Solar panel power | 3KW |
| Function | rectifier ,control |
| Operating environment | Temperature -30-60℃,humidity≤80% |
| PWM constant pressure voltage | ≥480Vdc |
| 3-phase load voltage 1 of the wind turbine | 560±5Vdc |
| 3-phase load voltage 2 of the wind turbine | ---- |
| Time-lapse of the wind turbine 3-phase load | 12-20 min |
| Low-valtage | ≤200Vdc |
| PWM Fuse | 32A |
| Solar Fuse | 10A |
| Fuse of DC output | 40A |
| Size of the controller | 560*400*240 mm |
| Weight of the controller | 23 Kg |
| Size of the load | 690*450*530 mm |
| Weight of the load | 36 Kg |
26KW Grid Tie Wind Turbine Controller
Product Characteristics
◆ Adopt two sets of control systems, PWM constant pressure system and three-phase load discharging system.
◆ PWM constant pressure control is 120% of the rated power of the wind turbine generator. In case of exceeding the scope of PWM constant pressure power, the three-phase load discharging will automatically start. After operation for 10-20 minutes, the three-phase load discharging will stop load discharging and the wind turbine generator will re-start to resume power supply, as a result, safe operation of the overall wind turbine generation system is ensured.
◆ Under the conditions of strong or super-strong wind, the controller will conduct constant pressure output and provide DC constant power supply to ensure normal operation of the inverter.
◆ Under the condition of disconnected grid-connected inverter, the controller will conduct constant pressure output to wait for inverter resumption.
◆ When the power grid is off, the three-phase load discharging of the controller will automatically start and the inverter will stop grid output. When the grid power resumes, the controller stops three-phase load discharging and the inverter will resume power supply.
◆ According to the category of the wind turbine generator, the controller can be additionally equipped with mechanical yawing, swing-tai, mechanical or hydraulic, pneumatic, magnetic and other brake functions.
◆ The inside of the controller is equipped with lightening protection device. Contain the transit over voltage penetrating into the wind turbine generator within the voltage scope bearable to the equipment or system or conduct the strong lightening current into the earth to avoid equipment damage posed by lightening impact.
◆ LED status indication: The frontal panel is equipped with indications of wind turbine generator, load discharging, stop delay time, under pressure, grid power and DC output voltage.
◆ Voltmeter indication: Indicate DC output voltage of the controller.
◆ The controller is equipped with emergency stop switch; in case of emergency, press down the emergency stop button in the front panel to cut off all power supply of the controller and the wind turbine generator will immediately carry out three-phase load discharging.
◆ The controller is equipped with manual three-phase load discharging switch; the user may use it according to actual circumstances. When using this switch, the wind turbine generator will forcibly carry out three-phase load discharging.
Technical Parameters
Above parameter only for reference
1. Could be custom made to user specifications.
2. Could have solar power control subject to user demand.
| Model | LCS-WCC-14 26KW |
| Wind power | 20KW |
| Solar panel power | 6KW |
| Function | rectifier ,control |
| Operating environment | Temperature -30-60℃,humidity≤80% |
| PWM constant pressure voltage | ≥480Vdc |
| 3-phase load voltage 1 of the wind turbine | 560±5Vdc |
| 3-phase load voltage 2 of the wind turbine | 570±5Vdc |
| Time-lapse of the wind turbine 3-phase load | 12-20 min |
| Low-voltage | ≤200Vdc |
| PWM Fuse | 63A |
| Solar Fuse | 16A |
| Fuse of DC output | 80A |
| Size of the controller | 570*550*330 mm |
| Weight of the controller | 30 Kg |
| Size of the load | 810*580*980 mm |
| Weight of the load | 77 Kg |
Request a Quote